Datasheet: View
Features | Values | Unit |
---|---|---|
Maximum Gate Trigger Current | 40 | mA |
Maximum Gate Trigger Voltage | 2 | V |
Maximum Holding Current | 20 | mA |
Rated Average On-State Current | 22.3 | A |
Repetitive Peak Forward Blocking Voltage | 600 | V |
Repetitive Peak Reverse Voltage | 600 | V |
Surge Current Rating | 230 | A |